cccc

FAIRBANG BIRDSCARER SERVICING

TO CHECK AND SERVICE YOUR FAIRBANG  FOLLOW THE FOLLOWING PROCEDURE

1)   TURN GAS OFF ,connect a battery , remove spark plug and check the gap should be 3mm , reattach plug to ignition lead and holding the lead place the thread of the spark plug against the bolt which holds the gas jet and block in place .  

Press the test switch and after 5 seconds the gas valve should click open and a few seconds later close the spark should then be observed jumping across the gap of  the plug making a buzzing noise . Replace plug into back of birdscarer

No spark try a different plug , ignition lead or coil , finally if still no spark the control box is faulty , return for repair .

2)  Gas valve , to check gas valve remove the white lead and put 12v from a battery directly across the terminals of the valve to open and close it . Remove the gas block and jet,  check the jet is clear and gas passes through  , clean if required.

Replace the gas block and jet into the tube ensure the jet is at the bottom of the airholes .

No gas flowing , jet blocked , valve jammed , control box faulty ,

3) Still  No bang , check regulator is regulating to 1 bar if pressure to high or low then no bang , gas chamber is clear of debris ( nests etc) Still stuck then contact us for advice

D.M.Electronics Ltd

Tel 01969 622778  

Fairbang@btinternet.com